Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Lobby camera phone DRC-GAC/GAB
User Manual
- Feature -
Covers all building with UPT cable.
RF/ID (function optional)
Vue de la page 0
1 2 3 4 5 6 ... 36 37

Résumé du contenu

Page 1 - User Manual

• Thank you for purchasing COMMAX products.• Please carefully read this User’s Guide (in particular, precautions for safety) before using a product an

Page 2 - 1. Greetings

- 9-5. Setting PIN5-1. Management PIN Setup✽ P - Old Management PIN - E - 0 - E - New PIN -E✽ Management PIN must be 4-digits long.✽ 0000 will not be

Page 3 - 2. Warning for safety

- 10 -5-2. Building PIN Setup✽ P - Old Management PIN - E - 1 - E - New PIN - E✽ Building PIN must be 4-digits long.✽0000 will not be recognized as a

Page 4 - Cleaning & Use

- 11 -5-3. Household PIN Setup✽K - Program Number - E - Household Number - E - Old Household PIN - E - New PIN - P✽ Household PIN must be 4-digits lon

Page 5 - 3. Overview

- 12 -6.Household PIN Confirmation6-1. Household PIN Confirmation✽ P - Management PIN - E - Program Number - E - Household Number - E① Press the Progr

Page 6 - 3-2 Essentials

- 13-✽① Press the Program button (P). (‘Prog’will appear)② Enter the Management PIN.③ Press the Call button (E).④ Press the Program Number (3) .⑤ Pr

Page 7

- 14-8. Using Remote Cardkeys (RF/ID) - Optional8-1. Testing Remote Cardkeys✽ P - Management PIN - E - 9 - E - Card Test - X (Cancel)✽ This feature is

Page 8 - Start again from the

- 15-8-2. Remote Cardkey Registration✽ P - Management PIN - E - 10 - E - Card Registration - X (Cancel)<Note>CdSv: Newly Registered Card (Succes

Page 9 - 4. PIN Types

- 16-8-3. Individual Deletion of Remote Cardkeys✽ P - Management PIN - E - 12 - E - Card Deletion - X (Cancel)① Press the Program button (P). (‘Prog’w

Page 10 - 5. Setting PIN

- 17-8-4. Confirming Remote Cardkey Registration✽ P - Management PIN - E - 13 - E - Card Confirmation - X (Cancel)① Press the Program button (P). (‘Pr

Page 11 - 5-2. Building PIN Setup

- 18-8-5. All Remote Cardkey deletion✽ P - Management PIN - E - 11 - E - E✽ Refrain from deleting all Remote Cardkeys, except for during installation.

Page 12 - 5-3. Household PIN Setup

- 1-the Main Entrance Interphone (RF/ID) - Optional9. Electronic key setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13 - 6.Household PIN Confirmation

- 19-9. Electronic key setting ✽ P - Management PIN - E - 8 - E - 0 – E : Deactivate usage of electronic keys (Available PIN number access) ✽P - Mana

Page 14

- 20-10. Door Release Time Setup✽ P - Management PIN - E - 4 - E - Door Release Time - E ✽This feature adjusts the door release time.① Press the Progr

Page 15 - 8-1. Testing Remote Cardkeys

11. Line Call Setup ✽ P - Management PIN - E - 21 - E - 0 - E : All calls ✽P - Management PIN - E - 21 - E – 0103 - E : Line call ex) This function is

Page 16 - <Caution>

- 22-✽P - Management PIN - E - 5 - E - 0 - E: Melody Tone ✽ P - Management PIN - E - 5 - E - 1 - E: Bell (Ringer)✽This feature sets the Recall tone he

Page 17

- 23-✽ P - Management PIN - E - 7 - E - 0 - E: Constant call✽P - Management PIN - E - 7 - E - 1 - E: Call once✽This function is to set the call sound

Page 18 - Confirm Card

- 24-Press the Program button (P).Enter the Management PIN.Press the Call button (E).The current capacityis displayed.Press the Call button (E).Press

Page 19

- 25-15. Input Household number✽ P - Management PIN - E - 15 - E - Household Number - E-Multi Sub number - E ✽ This function is for inputting househol

Page 20 - 9. Electronic key setting

- 26-<Multi sub number>✽ What is Multi sub number? In case that one household have more than one unit, assigned number to identifyevery unit for

Page 21 - 10. Door Release Time Setup

- 27-Enter theHousehold Number.Press the Guard button. Press the Page button.A paging tone will sound.Wait for a replyWait for a replyPress the page b

Page 22 - 11. Line Call Setup

- 28-✽ Household Number - K - Household PIN - E✽O - K - Building (Management) PIN - EEnter the Household Number.Press the Guard button.Enter the House

Page 23 - 12. Page Signal Selection

Please follow the things described below in order to prevent anydanger or property damage.WarningCautionProhibition.No disassemblyNo touchMust follow

Page 24

- 29-✽ Various PIN Programs1. P - Old Management PIN - E - 0 - E - New PIN- E: Management PIN Change 2. P- Old Management PIN -E -1 - E - New PIN - E:

Page 25

- 30-✽ Calling to household from lobby phone✽ Household number – EPress the household number Press the Call button.ex)In case of household 101 Emit ca

Page 26 - 15. Input Household number

22. Wiring Method1) Lobby camera phone(DRC-GAC/GAB)- 31-

Page 27 - <Multi sub number>

2) System Schematic- 32-

Page 28 - 17. Paging the Guardhouse

3) Terminal Board Wiring Diagram- 33-

Page 29

3) DRC-GAC Expansion- 34-

Page 30

※Please carefully read this User’s Guide before calling service man After checking the entire check list, please contact customer service center. Wewi

Page 31 - 21. How to use lobby phone

513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, KoreaInt’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133Web site : w

Page 32 - 22. Wiring Method

- 3-Cleaning & UsePlease don’tdisassemble,repair or rebuild this productarbitrarily (please contact theservice center if a repair isneeded. ·It ma

Page 33 - 2) System Schematic

- 4 -3-1. Part name①②③④⑤⑥⑨⑩⑪⑫⑬⑭⑧⑦3. Overview No FUN No FUN1. C-MIC 2. CAMERA 3. SPEAKER 4. FND DISPLAY 5.

Page 34

- 5-3-2 Essentials✽ RF/ID Receiver ⑤ (Optional)To open the door using a Remote Cardkey, place the key here. The word ‘oPEn’willdisplay and the door wi

Page 35 - 3) DRC-GAC Expansion

- 6-✽ Cancel Button ⑪ (X: Cancel)This button is used to cancel the current operation.✽ Talk volume controller ⑬Talk volume is adjustable by switching

Page 36 - 24. Specifications

- 7-● Must Know Before Use!1) Accessing All Features with the Program Button-When an error has been made as indicated by continuous beeps, pleasecance

Page 37 - Web site : www.commax.com

- 8-4. PIN Types4-1. Management PIN- This PIN is for use by the person in charge of the Management Office.- By default, this PIN is set as 4321.- Mana